Boster’s human EDIL3 ELISA Kit was based on standard sandwich enzyme-linked immune-sorbent assay technology. A monoclonal antibody from mouse specific for EDIL3 has been precoated onto 96-well plates. Standards(Expression system for standard: NSO, Immunogen sequence: D24-E480) and test samples are added to the wells, a biotinylated detection polyclonal antibody from goat specific for EDIL3 is added subsequently and then followed by washing with PBS or TBS buffer. Avidin-Biotin-Peroxidase Complex was added and unbound conjugates were washed away with PBS or TBS buffer. HRP substrate TMB was used to visualize HRP enzymatic reaction. TMB was catalyzed by HRP to produce a blue color product that changed into yellow after adding acidic stop solution. The density of yellow is proportional to the human EDIL3 amount of sample captured in plate.


Synonyms: DEL1 | Developmental endothelial locus 1 | Edil3 | Integrin binding protein DEL1 | Integrin-binding protein DEL1 | O43854

Species: human EDIL3

Assay: 15.6pg/ml-1000pg/ml

Sensitivy: <10pg/ml Specifity: Natural and recombinant human EDIL3

Cross Reactivity: There is no detectable cross-reactivity with other relevant proteins.

Antibodies: a monoclonal antibody from mouse|a biotinylated polyclonal antibody from goat

Anticoagulant: heparin or EDTA

Immunogen: NSO, D24-E480

Gene name: EGF-like repeat and discoidin I-like domain-containing protein 3 / EGF like repeats and discoidin domains 3

Protein name: EGF-like repeat and discoidin I-like domain-containing protein 3

Storage: Store at 4˚C for 6 months, at -20˚C for 12 months. Avoid multiple freeze-thaw cycles(Shipped with wet ice.)


|Intra-Assay Precision|Inter-Assay Precision
Sample|1|2|3|1|2|3
n|16|16|16|24|24|24
Mean(pg/ml)|39|255|385|39|236|411
Standard deviation|1.95|14.53|26.95|2.3|16.28|31.64
CV(%)|5%|5.7%|7%|5.9%|6.9%|7.7%


Reproducibility

To assay reproducibility, three samples with differing target protein concentrations were assayed using four different lots.

Lots Lot1 (pg/ml) Lot2 (pg/ml) Lot3 (pg/ml) Lot4 (pg/ml) Mean (pg/ml) Standard Deviation CV (%)
Sample 1 39 36 36 42 38 2.48 6.5%
Sample 2 255 251 234 209 237 18.11 7.6%
Sample 3 385 432 382 422 405 22.06 5.4%

*number of samples for each test n=16.


Catalog number|Description|Quantity
EK1500-CAP|96-well plate precoated with anti- human EDIL3 antibody|1
EK1500-ST|Lyophilized recombinant human EDIL3 standard|10ng/tube×2
EK1500-DA|Biotinylated anti- human EDIL3 antibody|130μl(dilution 1:100)
AR1103|Avidin-Biotin-Peroxidase Complex (ABC)|130μl(dilution 1:100)
AR1106-1|Sample diluent buffer|30ml
AR1106-2|Antibody diluent buffer|12ml
AR1106-3|ABC diluent buffer|12ml
AR1104|TMB color developing agent|10ml
AR1105|TMB stop solution|10ml
PLA-SEA|Adhesive cover|4