Rat GDF5 PicoKine ELISA Kit

Brand:
Boster Bio
Storage:

For quantitative detection of rat GDF5 in cell culture supernates, cell lysates, serum and plasma (heparin, EDTA).   

 

Available on backorder

SKU: EK1504 Category:

Description

Boster’s rat GDF5 ELISA Kit is based on standard sandwich enzyme-linked immune-sorbent assay technology. A monoclonal antibody from mouse specific for GDF5 has been precoated onto 96-well plates. Standards(Expression system for standard: E.coli, Immunogen sequence: A376-R495) and test samples are added to the wells, a biotinylated detection polyclonal antibody from goat specific for GDF5 is added subsequently and then followed by washing with PBS or TBS buffer. Avidin-Biotin-Peroxidase Complex is added and unbound conjugates are washed away with PBS or TBS buffer. HRP substrate TMB are used to visualize HRP enzymatic reaction. TMB is catalyzed by HRP to produce a blue color product that changed into yellow after adding acidic stop solution. The density of yellow is proportional to the rat GDF5 amount of sample captured in plate.


Synonyms: BMP14 | CDMP-1 | CDMP1 | GDF-5 | GDF5 | LAP4 | OS5 | Radotermin | SYNS2 | Q8K4X5

Species: rat GDF5

Assay: 31.2pg/ml-2000pg/ml

Sensitivy: <10pg/ml Specifity: Natural and recombinant rat GDF5

Cross Reactivity: There is no detectable cross-reactivity with other relevant proteins.

Antibodies: a monoclonal antibody from mouse|a biotinylated polyclonal antibody from goat

Anticoagulant: heparin or EDTA

Immunogen: E.coli, A376-R495

Gene name: Growth and differentiation factor-5 / growth differentiation factor 5

Protein name: Growth and differentiation factor-5

Storage: Store at 4˚C for 6 months, at -20˚C for 12 months. Avoid multiple freeze-thaw cycles(Shipped with wet ice.)


|Intra-Assay Precision|Inter-Assay Precision
Sample|1|2|3|1|2|3
n|16|16|16|24|24|24
Mean(pg/ml)|60|323|894|59|339|908
Standard deviation|3.84|14.53|50.06|4.72|21.01|57.2
CV(%)|6.4%|4.5%|5.6%|8%|6.2%|6.3%


Reproducibility

To assay reproducibility, three samples with differing target protein concentrations were assayed using four different lots.

Lots Lot1 (pg/ml) Lot2 (pg/ml) Lot3 (pg/ml) Lot4 (pg/ml) Mean (pg/ml) Standard Deviation CV (%)
Sample 1 60 59 68 62 62 3.49 5.6%
Sample 2 323 317 316 281 309 16.52 5.3%
Sample 3 894 859 910 831 873 30.69 3.5%

*number of samples for each test n=16.


Catalog number|Description|Quantity
EK1504-CAP|96-well plate precoated with anti- rat GDF5 antibody|1
EK1504-ST|Lyophilized recombinant rat GDF5 standard|10ng/tube×2
EK1504-DA|Biotinylated anti- rat GDF5 antibody|130μl(dilution 1:100)
AR1103|Avidin-Biotin-Peroxidase Complex (ABC)|130μl(dilution 1:100)
AR1106-1|Sample diluent buffer|30ml
AR1106-2|Antibody diluent buffer|12ml
AR1106-3|ABC diluent buffer|12ml
AR1104|TMB color developing agent|10ml
AR1105|TMB stop solution|10ml
PLA-SEA|Adhesive cover|4