Description
Boster’s Human LILRA3 ELISA Kit is based on standard sandwich enzyme-linked immune-sorbent assay technology. A polyclonal antibody from goat specific for LILRA3 has been precoated onto 96-well plates. Standards(Expression system for standard: NSO, Immunogen sequence: G24-E439) and test samples are added to the wells, a biotinylated detection polyclonal antibody from goat specific for LILRA3 is added subsequently and then followed by washing with PBS or TBS buffer. Avidin-Biotin-Peroxidase Complex is added and unbound conjugates are washed away with PBS or TBS buffer. HRP substrate TMB are used to visualize HRP enzymatic reaction. TMB is catalyzed by HRP to produce a blue color product that changed into yellow after adding acidic stop solution. The density of yellow is proportional to the human LILRA3 amount of sample captured in plate.
Synonyms: HM31; HM43; ILT6; LIR4; CD85E; ILT-6; LIR-4
Species: Human LILRA3
Assay: 312pg/ml-20000pg/ml
Sensitivy: <10pg/ml Specifity: Natural and recombinant human LILRA3
Cross Reactivity: There is no detectable cross-reactivity with other relevant proteins.
Antibodies: a polyclonal antibody from goat|a biotinylated polyclonal antibody from goat
Anticoagulant: heparin, EDTA or citrate
Immunogen: NSO, G24-E439
Gene name: Leukocyte immunoglobulin-like receptor subfamily A member 3 / leukocyte immunoglobulin like receptor A3
Protein name: Leukocyte immunoglobulin-like receptor subfamily A member 3
Storage: Store at 4˚C for 6 months, at -20˚C for 12 months. Avoid multiple freeze-thaw cycles(Shipped with wet ice.)
|Intra-Assay Precision|Inter-Assay Precision
Sample|1|2|3|1|2|3
n|16|16|16|24|24|24
Mean(pg/ml)|534|2702|8939|578|2835|9176
Standard deviation|26.17|154.01|688.30|41.62|238.14|835.02
CV(%)|4.9%|5.7%|7.7%|7.2%|8.4%|9.1%
Reproducibility
To assay reproducibility, three samples with differing target protein concentrations were assayed using four different lots.
Lots | Lot1 (pg/ml) | Lot2 (pg/ml) | Lot3 (pg/ml) | Lot4 (pg/ml) | Mean (pg/ml) | Standard Deviation | CV (%) |
---|---|---|---|---|---|---|---|
Sample 1 | 534 | 575 | 581 | 544 | 559 | 31.86 | 5.7% |
Sample 2 | 2702 | 2815 | 2838 | 2912 | 2817 | 174.65 | 6.2% |
Sample 3 | 8939 | 9116 | 8672 | 9284 | 9003 | 783.26 | 8.7% |
*number of samples for each test n=16.
Catalog number|Description|Quantity
EK2111-CAP|96-well plate precoated with anti- human LILRA3 antibody|1
EK2111-ST|Lyophilized recombinant human LILRA3 standard|20ng/tube×2
EK2122-DA|Biotinylated anti- human LILRA3 antibody|130μl(dilution 1:100)
AR1103|Avidin-Biotin-Peroxidase Complex (ABC)|130μl(dilution 1:100)
AR1106-1|Sample diluent buffer|30ml
AR1106-2|Antibody diluent buffer|12ml
AR1106-3|ABC diluent buffer|12ml
AR1104|TMB color developing agent|10ml
AR1105|TMB stop solution|10ml
PLA-SEA|Adhesive cover|4