Human GAS1 PicoKine ELISA Kit

Brand:
Boster Bio
Storage:

For quantitative detection of human GAS1 in cell culture supernates, serum and plasma (heparin, EDTA).   

 

Available on backorder

SKU: EK2044 Category:

Description

Boster’s human GAS1 ELISA Kit is based on standard sandwich enzyme-linked immune-sorbent assay technology. A monoclonal antibody from mouse specific for GAS1 has been precoated onto 96-well plates. Standards(Expression system for standard: NSO, Immunogen sequence: L40-S318) and test samples are added to the wells, a biotinylated detection polyclonal antibody from goat specific for GAS1 is added subsequently and then followed by washing with PBS or TBS buffer. Avidin-Biotin-Peroxidase Complex is added and unbound conjugates are washed away with PBS or TBS buffer. HRP substrate TMB are used to visualize HRP enzymatic reaction. TMB is catalyzed by HRP to produce a blue color product that changed into yellow after adding acidic stop solution. The density of yellow is proportional to the human GAS1 amount of sample captured in plate.


Synonyms: Growth arrest-specific protein 1; GAS-1; GAS1

Species: Human GAS1

Assay: 31.2pg/ml-2000pg/ml

Sensitivy: <10pg/ml Specifity: Natural and recombinant human GAS1

Cross Reactivity: There is no detectable cross-reactivity with other relevant proteins.

Antibodies: a monoclonal antibody from mouse|a biotinylated polyclonal antibody from goat

Anticoagulant: heparin or EDTA

Immunogen: NSO, L40-S318

Gene name: Growth arrest-specific protein 1 / growth arrest specific 1

Protein name: Growth arrest-specific protein 1

Storage: Store at 4˚C for 6 months, at -20˚C for 12 months. Avoid multiple freeze-thaw cycles(Shipped with wet ice.)


|Intra-Assay Precision|Inter-Assay Precision
Sample|1|2|3|1|2|3
n|16|16|16|24|24|24
Mean(pg/ml)|55|228|845|60|239|884
Standard deviation|2.31|14.36|38.03|3.18|15.30|63.65
CV(%)|4.2%|6.3%|4.5%|5.3%|6.4%|7.2%


Reproducibility

To assay reproducibility, three samples with differing target protein concentrations were assayed using four different lots.

Lots Lot1 (pg/ml) Lot2 (pg/ml) Lot3 (pg/ml) Lot4 (pg/ml) Mean (pg/ml) Standard Deviation CV (%)
Sample 1 55 53 50 52 52 1.80 3.4%
Sample 2 228 261 228 264 245 17.28 7.0%
Sample 3 845 788 838 845 829 23.84 2.8%

*number of samples for each test n=16.


Catalog number|Description|Quantity
EK2044-CAP|96-well plate precoated with anti- human GAS1 antibody|1
EK2044-ST|Lyophilized recombinant human GAS1 standard|2ng/tube×2
EK2044-DA|Biotinylated anti- human GAS1 antibody|130μl(dilution 1:100)
AR1103|Avidin-Biotin-Peroxidase Complex (ABC)|130μl(dilution 1:100)
AR1106-1|Sample diluent buffer|30ml
AR1106-2|Antibody diluent buffer|12ml
AR1106-3|ABC diluent buffer|12ml
AR1104|TMB color developing agent|10ml
AR1105|TMB stop solution|10ml
PLA-SEA|Adhesive cover|4