Human VAP-1/AOC3 PicoKine ELISA Kit

Brand:
Boster Bio
Storage:

For Quantitative Detection of human VAP-1 in cell culture supernates, serum and plasma (heparin, EDTA).   

 

Available on backorder

SKU: EK1646 Category:

Description

Boster’s human VAP-1 ELISA Kit was based on standard sandwich enzyme-linked immune-sorbent assay technology. A monoclonal antibody from mouse specific for VAP-1 has been precoated onto 96-well plates. Standards (Expression system for standard: sf21, Immunogen sequence: N2-N763) and test samples are added to the wells, a biotinylated detection polyclonal antibody from goat specific for VAP-1 is added subsequently and then followed by washing with PBS or TBS buffer. Avidin-Biotin-Peroxidase Complex was added and unbound conjugates were washed away with PBS or TBS buffer. HRP substrate TMB was used to visualize HRP enzymatic reaction. TMB was catalyzed by HRP to produce a blue color product that changed into yellow after adding acidic stop solution. The density of yellow is proportional to the human VAP-1 amount of sample captured in plate.


Synonyms: Membrane primary amine oxidase

Species: Human VAP-1/AOC3

Assay: 0.78ng/ml-50ng/ml

Sensitivy: <20pg/ml Specifity: Natural and recombinant human VAP-1

Cross Reactivity: There is no detectable cross-reactivity with other relevant proteins.

Antibodies: a monoclonal antibody from mouse|a biotinylated polyclonal antibody from goat

Anticoagulant: heparin or EDTA

Immunogen: sf21,N2-N763

Gene name: Membrane primary amine oxidase / amine oxidase, copper containing 3

Protein name: Membrane primary amine oxidase

Storage: Store at 4˚C for 6 months, at -20˚C for 12 months. Avoid multiple freeze-thaw cycles(Shipped with wet ice.)


|Intra-Assay Precision|Inter-Assay Precision
Sample|1|2|3|1|2|3
n|16|16|16|24|24|24
Mean(pg/ml)|1035|5427|21122|1103|5962|23124
Standard deviation|72.45|260.49|1203.95|80.51|387.53|1364.31
CV(%)|7%|4.8%|5.7%|7.3%|6.5%|5.9%


Reproducibility

To assay reproducibility, three samples with differing target protein concentrations were assayed using four different lots.

Lots Lot1 (pg/ml) Lot2 (pg/ml) Lot3 (pg/ml) Lot4 (pg/ml) Mean (pg/ml) Standard Deviation CV (%)
Sample 1 1035 1027 1045 1029 1034 7 0.6%
Sample 2 5427 5489 4892 4736 5136 327.42 6.3%
Sample 3 21122 20989 20645 21778 21133 410.79 1.9%

*number of samples for each test n=16.


Catalog number|Description|Quantity
EK1646-CAP|96-well plate precoated with anti- human VAP-1 antibody|1
EK1646-ST|Lyophilized recombinant human VAP-1 standard|50ng/tube×2
EK1646-DA|Biotinylated anti- human VAP-1 antibody|130μl(dilution 1:100)
AR1103|Avidin-Biotin-Peroxidase Complex (ABC)|130μl(dilution 1:100)
AR1106-1|Sample diluent buffer|30 ml
AR1106-2|Antibody diluent buffer|12ml
AR1106-3|ABC diluent buffer|12ml
AR1104|TMB color developing agent|10ml
AR1105|TMB stop solution|10ml
PLA-SEA|Adhesive cover|4