Human WIF1 PicoKine ELISA Kit

Brand:
Boster Bio
Storage:

For quantitative detection of human WIF1 in cell culture supernates, cell lysates, serum and plasma (heparin, EDTA).   

 

Available on backorder

SKU: EK1524 Category:

Description

Boster’s human WIF1 ELISA Kit was based on standard sandwich enzyme-linked immune-sorbent assay technology. A monoclonal antibody from mouse specific for WIF1 has been precoated onto 96-well plates. Standards(Expression system for standard: NSO, Immunogen sequence: G29-W379) and test samples are added to the wells, a biotinylated detection polyclonal antibody from goat specific for WIF1 is added subsequently and then followed by washing with PBS or TBS buffer. Avidin-Biotin-Peroxidase Complex was added and unbound conjugates were washed away with PBS or TBS buffer. HRP substrate TMB was used to visualize HRP enzymatic reaction. TMB was catalyzed by HRP to produce a blue color product that changed into yellow after adding acidic stop solution. The density of yellow is proportional to the human WIF1 amount of sample captured in plate.


Synonyms: WIF1 | WIF-1 | Wnt inhibitory factor 1 | Q9Y5W5

Species: human WIF1

Assay: 23.4pg/ml-1500pg/ml

Sensitivy: <10pg/ml Specifity: Natural and recombinant human WIF1

Cross Reactivity: There is no detectable cross-reactivity with other relevant proteins.

Antibodies: a monoclonal antibody from mouse|a biotinylated polyclonal antibody from goat

Anticoagulant: heparin or EDTA

Immunogen: NSO, G29-W379

Gene name: Wnt inhibitory factor 1 / WNT inhibitory factor 1

Protein name: Wnt inhibitory factor 1

Storage: Store at 4˚C for 6 months, at -20˚C for 12 months. Avoid multiple freeze-thaw cycles(Shipped with wet ice.)


|Intra-Assay Precision|Inter-Assay Precision
Sample|1|2|3|1|2|3
n|16|16|16|24|24|24
Mean(pg/ml)|43|210|939|40|222|983
Standard deviation|2.06|11.76|46.95|2.64|15.98|67.82
CV(%)|4.8%|5.6%|5%|6.6%|7.2%|6.9%


Reproducibility

To assay reproducibility, three samples with differing target protein concentrations were assayed using four different lots.

Lots Lot1 (pg/ml) Lot2 (pg/ml) Lot3 (pg/ml) Lot4 (pg/ml) Mean (pg/ml) Standard Deviation CV (%)
Sample 1 43 39 39 39 40 1.73 4.3%
Sample 2 210 211 236 217 218 10.45 4.7%
Sample 3 939 920 839 864 890 40.54 4.5%

*number of samples for each test n=16.


Catalog number|Description|Quantity
EK1524-CAP|96-well plate precoated with anti- human WIF1 antibody|1
EK1524-ST|Lyophilized recombinant human WIF1 standard|10ng/tube×2
EK1524-DA|Biotinylated anti- human WIF1 antibody|130μl(dilution 1:100)
AR1103|Avidin-Biotin-Peroxidase Complex (ABC)|130μl(dilution 1:100)
AR1106-1|Sample diluent buffer|30ml
AR1106-2|Antibody diluent buffer|12ml
AR1106-3|ABC diluent buffer|12ml
AR1104|TMB color developing agent|10ml
AR1105|TMB stop solution|10ml
PLA-SEA|Adhesive cover|4